SSI · MATERIALS RESEARCH

Compare four Joule heating system models

Compare two hot-press sintering configurations and two rapid Joule-heating configurations using the approved SSI In-situ Research Systems catalogue. Choose by sample form, pressure, electrical service, heating profile and atmosphere—not temperature alone.

Four catalog models at a glance

Catalog-listed selection points; final configuration is confirmed by quotation
ModelPrimary configurationSample format / catalog quantityPressureHeating or current responseCatalog temperature scope
CIS-JHP-1030Hot-press sintering10, 20 or 30 mm diameter; 5–20 mm thickness3 T≤5000 °C/minMould maximum not lower than 2300 °C
CIS-JHP-2050Hot-press sintering20 or 50 mm diameter (customizable); 5–20 mm thickness10 T≤1200 °C/minMould maximum not lower than 2300 °C
CIS-JH-V4.0.0Rapid heat treatment / synthesisSample stage ≤100 × 15 × 0.2 mm; catalog test quantity 500 mgNot listed2 ms current ramp; 1 ms minimum pulse3000 °C; long-term heat preservation within 2000 °C
CIS-JH-V4.0.0-TDStreamlined rapid heat treatment / synthesisSample stage ≤55 × 10 × 0.05 mm; catalog test quantity 50 mgNot listed20 ms current ramp; 20 ms minimum pulse1800 °C; long-term heat preservation not listed

The hot-press figures come from catalogue physical pages 5–6; the flagship and streamlined rapid-heating figures come from pages 7–8. Values belong to their named models and must not be combined across variants.

CIS-JHP-1030 vs CIS-JHP-2050

Both hot-press models are listed with 380 V, 60 kW, 50/60 Hz electrical service (customizable), a graphite mould and infrared temperature measurement. The 1030 supports smaller listed sample diameters and 3 T pressure; the 2050 lists 20/50 mm samples and 10 T pressure.

The catalogue lists a faster controllable heating-rate limit for the 1030 and a larger cavity for the 2050. Confirm the mould, press load, sample drawing, chamber, gas lines, vacuum and cooling package.

Review the Hot-Press Joule Heating System family →

Request the hot-press configuration

CIS-JH-V4.0.0 vs V4.0.0-TD

The flagship V4.0.0 lists 3-phase 380 V / 40 A input, 0–40 V and 0–500 A output, water cooling and a fixed clamping electrode. The streamlined TD version lists AC 220 V / 16 A input, 0–12 V and 0–170 A output, air cooling and adjustable electrode spacing.

Both list 5 ms data collection, RS485 + Ethernet + USB communication, touch-screen/PC collection and infrared temperature measurement. Confirm the sample-stage material, chamber, gas line, pump, software and applicable temperature-measurement range.

Review the Joule Heating System family →

Request the rapid-heating configuration

Other verified Joule-heating families

This four-model table does not replace the wider catalog range. SSI also lists a continuous high-flux platform, externally assisted platform, rapid Joule-heating furnace, discharge-plasma system and long-duration system. These serve different production, field-assisted, furnace, plasma and heat-preservation requirements; they are not interchangeable model names.

What to send for a useful quotation

  1. Material, sample form, dimensions, mass or batch requirement.
  2. Target temperature, heating rate/profile, hold time and cooling requirement.
  3. Whether pressure, pulsed operation, plasma, quenching or an external field is required.
  4. Vacuum or gas atmosphere, gas paths, pump and chamber/interface requirements.
  5. Available electrical supply, cooling water/chiller, installation space and exhaust.
  6. Control, logging, communications, accessories, documentation and quantity.

SSI will review the model and supplied scope. Catalog limits are not a process guarantee, and material suitability must be assessed for the intended experiment.

Primary source: SSI In-situ Research Systems catalogue, physical pages 5–8.