Reference imageElectrodes & Holders
Ag/AgCl Reference Electrode
A silver/silver-chloride reference electrode matched to the electrolyte, filling solution and cell geometry.
SUPER SCIENTIFIC INSTRUMENTS
Find electrochemistry consumables, in-situ research systems, catalyst reactors and battery equipment. Browse by category or search by product, model or method.
Showing 179 of 179 products
Download catalogs ↗
Reference imageElectrodes & Holders
A silver/silver-chloride reference electrode matched to the electrolyte, filling solution and cell geometry.
Reference imageCarbon Materials & GDL
Carbon cloth substrates for gas-diffusion layers and laboratory electrode development.
Reference imageCarbon Materials & GDL
Carbon paper gas-diffusion substrates selected by grade, thickness, treatment and cut size.
Reference imageBattery Components
CR2032 coin-cell case requirements for laboratory cell assembly, with the required set contents defined.
Brochure photoMEA & Cell Hardware
Custom MEA enquiries combining membrane, electrode layers and the active area required by your laboratory cell.
Reference imageElectrodes & Holders
A glassy carbon working surface for laboratory voltammetry and electrochemical method development.
Range photoMembranes & Ionomers
D520-series Nafion ionomer dispersion enquiries for laboratory electrode and catalyst-ink formulations.
Range photoMembranes & Ionomers
Nafion N117 proton-exchange membrane enquiries for laboratory electrochemical cells and membrane research.
Range photoMembranes & Ionomers
Nafion NR211 membrane enquiries for research assemblies that specify a thin solution-cast PFSA membrane.
Range photoMembranes & Ionomers
Nafion NR212, also requested as N212, for fuel-cell and electrochemical membrane requirements.
Reference imageFoams, Felts & Foils
Nickel felt for porous-electrode and catalyst-support requirements with a defined material and thickness specification.
Reference imageFoams, Felts & Foils
Porous nickel foam specified by thickness, cut size and pore-structure requirements.
Brochure photoCatalysts & Inks
Pt/C catalyst enquiries with the required platinum fraction, carbon support and research quantity.
Reference imageElectrodes & Holders
Platinum wire electrodes for laboratory cell configurations requiring a specified wire diameter, length and connection.
Catalog imageResearch Cells & Fixtures
A quick-opening PEEK cell for entry-level three-electrode gas-diffusion experiments.
Catalog imageResearch Cells & Fixtures
A three-chamber PEEK gas-diffusion cell with a catalog reaction area of 1 cm².
Catalog imageResearch Cells & Fixtures
A window-equipped three-chamber gas-diffusion cell with 7 mm anode-to-cathode spacing.
Catalog imageResearch Cells & Fixtures
A window-equipped three-chamber gas-diffusion cell with a shorter 3 mm anode-to-cathode gap.
Reference imageCarbon Materials & GDL
Activated carbon for research projects with a defined grade, physical form and material requirement.
Reference imageFoams, Felts & Foils
Porous aluminium foam specified by thickness, cut size and pore-structure requirements.
Reference imageFoams, Felts & Foils
Aluminium foil specified for laboratory electrode preparation and current-collector development.
Reference imageFoams, Felts & Foils
Aluminium Plate material enquiries for laboratory samples, cell components and current-collector requirements.
Reference imageBattery Components
Aluminium-laminated film for laboratory pouch-cell development and packaging-material requirements.
Range photoResearch Cells & Fixtures
Analytical electrochemical cell arrangements with a support stand and the required electrode layout.
Reference imageMembranes & Ionomers
Anion-exchange membrane requirements for research cells, selected by chemistry, grade and the intended assembly.
Catalog imageBattery Characterisation
Aqueous-Battery In-Situ AFM Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
ATR Heating Crystal Plate for laboratory research and application-specific experimental configurations.
Catalog imageResearch Cells & Fixtures
A vanadium redox flow battery research cell with a catalog flow-channel area of 50 cm².
Catalog imageResearch Cells & Fixtures
A PEEK compression-type battery test cell with an Ag/AgCl reference-electrode connection.
Catalog imageResearch Cells & Fixtures
A two-electrode compression-type cell for simulated coin-cell tests using 10, 12 or 16 mm wafers.
Catalog imageResearch Cells & Fixtures
A two-electrode battery test cell with optical windows for observing the electrochemical experiment.
Catalog imageResearch Cells & Fixtures
A visual battery test cell that adds a reference-electrode port to the B001-3 arrangement.
Catalog imageIn-Situ Spectroscopy & Diffraction
Button-Cell In-Situ Mass Spectrometry Cell for laboratory research and application-specific experimental configurations.
Catalog imageResearch Cells & Fixtures
An ECL test cell with a bottom detection channel and a fixed 1 cm² working area for ITO or FTO glass.
Catalog imageResearch Cells & Fixtures
A basic in-situ Raman cell with a 37 mm quartz window and a standard 1 cm² working area.
Catalog imageResearch Cells & Fixtures
A two-compartment Raman cell with a removable membrane arrangement and a standard 1 cm² working area.
Catalog imageResearch Cells & Fixtures
An in-situ Raman cell that adds a cathode gas channel for gas-diffusion electrode measurements.
Catalog imageResearch Cells & Fixtures
A membrane conductivity fixture using PEEK and platinum sheets with a two-electrode measurement arrangement.
Catalog imageResearch Cells & Fixtures
A membrane conductivity fixture with platinum wires supporting two- and four-electrode measurements.
Catalog imageResearch Cells & Fixtures
Research cells for capacitive-deionization studies with a stated electrode geometry and fluid arrangement.
Reference imageCarbon Materials & GDL
Carbon felt substrates for laboratories specifying a porous carbon electrode material.
Reference imageCarbon Materials & GDL
A coated aluminium foil substrate specified by its base material, dimensions and coating requirement.
Reference imageCarbon Materials & GDL
A coated carbon cloth substrate specified by its base material, dimensions and coating requirement.
Reference imageCarbon Materials & GDL
A coated copper foil substrate specified by its base material, dimensions and coating requirement.
Brochure photoMEA & Cell Hardware
Catalyst-coated membranes configured by membrane grade, catalyst layers and the required active area.
Range photoMembranes & Ionomers
Cation-exchange membranes specified by grade, ionic form, thickness and cell dimensions.
Reference imageBattery Components
Cellulose-based separators selected by grade, thickness and the intended cell chemistry.
Reference imageResearch Cells & Fixtures
Laboratory cells and kits for electrochemical coating, paint and corrosion studies with a defined sample area.
Reference imageBattery Components
Coin-cell holders for a specified cell format and electrical or mechanical test interface.
Reference imageBattery Components
Mesh components for coin-cell and laboratory battery assemblies, specified by material and geometry.
Catalog imageBattery Fabrication Equipment
Coin-Cell Fabrication Equipment Line for laboratory and pilot-scale battery fabrication workflows.
Catalog imageIn-Situ Spectroscopy & Diffraction
Composite ATR Accessories for laboratory research and application-specific experimental configurations.
Reference imageCarbon Materials & GDL
Conductive carbon powder for electrode formulations requiring a stated grade and material specification.
Catalog imageJoule Heating Systems
Continuous High-Flux Joule Heating Platform for laboratory research and application-specific experimental configurations.
Range photoElectrodes & Holders
An electrode holder selected around the copper electrode shape and its exposed portion.
Reference imageFoams, Felts & Foils
Porous copper foam specified by thickness, cut size and pore-structure requirements.
Reference imageFoams, Felts & Foils
Copper foil for laboratory current-collector and thin-metal-substrate requirements.
Reference imageFoams, Felts & Foils
Copper Plate material enquiries for laboratory samples, cell components and current-collector requirements.
Range photoElectrodes & Holders
Copper working electrodes for experiments requiring a specified copper surface and mounting geometry.
Brochure photoResearch Cells & Fixtures
Laboratory cells for CO₂ electrochemical-reduction studies, configured around the required electrode and flow arrangement.
Catalog imageResearch Cells & Fixtures
Gas-diffusion flow cells with 10 × 10 mm or 20 × 20 mm standard channels and selectable body materials.
Catalog imageBattery Fabrication Equipment
Cylindrical-Cell Fabrication Equipment Line for laboratory and pilot-scale battery fabrication workflows.
Catalog imageBattery Characterisation
Dendrite Observation Optical System for laboratory research and application-specific experimental configurations.
Reference imageElectrodes & Holders
A detachable glassy carbon electrode arrangement for laboratories specifying a removable working surface.
Catalog imageJoule Heating Systems
Discharge Plasma Joule Heating System for laboratory research and application-specific experimental configurations.
Catalog imageResearch Cells & Fixtures
A laboratory CDI cell with PMMA protective plates and a catalog electrode spacing below 3 mm.
Catalog imageResearch Cells & Fixtures
A CDI cell with a serpentine graphite current collector and a 50 × 50 × 2 mm internal flow channel.
Catalog imageIn-Situ Spectroscopy & Diffraction
Electric-Field Diffuse-Reflectance Cell for laboratory research and application-specific experimental configurations.
Brochure photoCatalysts & Inks
Electrocatalyst inks specified for coating electrodes or membranes, with catalyst, binder and quantity defined.
Catalog imageResearch Cells & Fixtures
Electrochemical flow cells configured by electrode geometry, flow paths and the required fluid connections.
Catalog imageIn-Situ Spectroscopy & Diffraction
Electrochemical Mass Spectrometry Cell for laboratory research and application-specific experimental configurations.
Reference imageElectrodes & Holders
Polishing consumables and accessories selected for the material and finish of your working electrodes.
Brochure photoMEA & Cell Hardware
Research electrolyzer hardware selected by cell chemistry, active area and plate or current-collector materials.
Catalog imageJoule Heating Systems
Externally Assisted Joule Heating Platform for laboratory research and application-specific experimental configurations.
Brochure photoMEA & Cell Hardware
Laboratory fuel-cell hardware configured around an active area, flow-field arrangement and material requirement.
Catalog imageBattery Characterisation
Fuel-Cell In-Situ Raman Test Cell for laboratory research and application-specific experimental configurations.
Catalog imageBattery Characterisation
Fuel-Cell In-Situ XAFS Test Cell for laboratory research and application-specific experimental configurations.
Reference imageMEA & Cell Hardware
Gas-diffusion electrodes specified by substrate, catalyst, active area and metal loading.
Brochure photoCatalysts & Inks
Carbon-based gas-diffusion-layer inks specified for microporous-layer and electrode-substrate coating requirements.
Catalog imageCatalyst Reactors & Gas Systems
Gas Mixing System for laboratory research and application-specific experimental configurations.
Brochure photoLaboratory Filters
Glass microfiber laboratory filters selected by grade, dimensions and the requirements of the filtration method.
Reference imageElectrodes & Holders
Gold working electrodes for studies that require a defined metallic electrochemical surface.
Reference imageCarbon Materials & GDL
Graphite powder selected by grade, particle requirements and the intended electrode formulation.
Reference imageElectrodes & Holders
Graphite rod electrodes specified by rod diameter, usable length and the laboratory connection.
Reference imageResearch Cells & Fixtures
H-type laboratory electrochemical cells selected by chamber volume, separation and electrode arrangement.
Catalog imageIn-Situ Spectroscopy & Diffraction
H-Type Infrared Internal-Reflection Cell for laboratory research and application-specific experimental configurations.
Reference imageCarbon Materials & GDL
Hard-carbon material enquiries for laboratory electrode and energy-storage research.
Catalog imageIn-Situ Spectroscopy & Diffraction
Heterogeneous Photocatalytic In-Situ XAFS Cell for laboratory research and application-specific experimental configurations.
Reference imageElectrodes & Holders
Mercury/mercury-oxide reference electrodes specified with the filling electrolyte and laboratory interface.
Reference imageElectrodes & Holders
A mercury/mercurous-sulfate reference electrode selected by filling solution, junction and cell fit.
Catalog imageBattery Characterisation
High- and Low-Temperature Battery Raman Test Cell for laboratory research and application-specific experimental configurations.
Catalog imageBattery Characterisation
High- and Low-Temperature Battery XAFS Transmission Cell for laboratory research and application-specific experimental configurations.
Catalog imageBattery Characterisation
High- and Low-Temperature Battery XRD Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
High- and Low-Temperature Diffuse-Reflectance Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
High-Temperature Dual-Mode XAFS Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
High-Temperature High-Pressure Diffuse-Reflectance Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
High-Temperature High-Pressure XAFS Reaction Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
High-Temperature In-Situ Raman Reaction Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
High-Temperature In-Situ XRD Reaction Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
High-Temperature Infrared Transmission Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
High-Temperature Photocatalytic XRD Reaction Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
High-Temperature Plasma Diffuse-Reflectance Cell for laboratory research and application-specific experimental configurations.
Range photoElectrodes & Holders
Reference electrode configurations for applications with a stated elevated-temperature requirement.
Catalog imageIn-Situ Spectroscopy & Diffraction
High-Temperature Stirring H-Type ATR Cell for laboratory research and application-specific experimental configurations.
Catalog imageJoule Heating Systems
Hot-Press Joule Heating System for laboratory research and application-specific experimental configurations.
Reference imageElectrodes & Holders
Hydrogen-reference arrangements for laboratories requiring a defined reference configuration.
Catalog imageIn-Situ Spectroscopy & Diffraction
In-Situ Differential Mass Spectrometry System for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
In-Situ Infrared Diffuse-Reflectance System for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
In-Situ Infrared Electrochemical ATR System for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
In-Situ Infrared External-Reflection Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
In-Situ Infrared Multiple-Reflection Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
In-Situ Infrared Transmission System for laboratory research and application-specific experimental configurations.
Catalog imageResearch Cells & Fixtures
Electrochemical cells configured for in-situ Raman measurements and the required optical arrangement.
Catalog imageIn-Situ Spectroscopy & Diffraction
In-Situ XRD Electrochemical Reaction Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
Infrared–Mass Spectrometry Tandem Cell for laboratory research and application-specific experimental configurations.
Brochure photoCatalysts & Inks
Iridium oxide catalyst enquiries with the required grade, purity and laboratory quantity.
Catalog imageJoule Heating Systems
Joule Heating System for laboratory research and application-specific experimental configurations.
Catalog imageCatalyst Reactors & Gas Systems
Joule-Heated Fixed-Bed Reactor for laboratory research and application-specific experimental configurations.
Catalog imageBattery Characterisation
Lithium and Sodium Battery UV Electrolyte Test Cell for laboratory research and application-specific experimental configurations.
Reference imageBattery Components
Lithium chips for laboratory cell requirements with a defined diameter, thickness and material specification.
Catalog imageBattery Characterisation
Lithium Dendrite Microscopic Observation Cells for laboratory research and application-specific experimental configurations.
Catalog imageBattery Characterisation
Lithium-Air Battery In-Situ Raman Test Cell for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
Lithium-Battery In-Situ Infrared ATR Cell for laboratory research and application-specific experimental configurations.
Catalog imageBattery Characterisation
Lithium-Battery In-Situ Raman Test Cell for laboratory research and application-specific experimental configurations.
Catalog imageBattery Characterisation
Lithium-Battery In-Situ XAFS Test Cell for laboratory research and application-specific experimental configurations.
Catalog imageBattery Characterisation
Lithium-Battery In-Situ XRD Cell for laboratory research and application-specific experimental configurations.
Catalog imageJoule Heating Systems
Long-Duration Joule Heating System for laboratory research and application-specific experimental configurations.
Catalog imageIn-Situ Spectroscopy & Diffraction
Low-Temperature In-Situ XRD Reaction Cell for laboratory research and application-specific experimental configurations.
Reference imageFoams, Felts & Foils
Magnesium foil for laboratories specifying a thin metallic research substrate.
Catalog imageResearch Cells & Fixtures
Conductivity measurement fixtures configured by sample dimensions, contact geometry and the measurement method.
Catalog imageCatalyst Reactors & Gas Systems
Miniature Fixed-Bed Reactor for laboratory research and application-specific experimental configurations.
Catalog imageCatalyst Reactors & Gas Systems
Molecular Pump and Vacuum System for laboratory research and application-specific experimental configurations.
Reference imageFoams, Felts & Foils
Molybdenum foil specified by thickness, dimensions and the required material grade.
Catalog imageCatalyst Reactors & Gas Systems
Multichannel Fixed-Bed Reactor for laboratory research and application-specific experimental configurations.
Reference imageBattery Components
Nickel tabs specified by dimensions, thickness and the required cell connection arrangement.
Range photoElectrodes & Holders
Nickel working electrodes for defined-surface laboratory studies and electrode-material development.
Reference imageElectrodes & Holders
Reference electrodes configured for non-aqueous electrochemical measurements and the required solvent system.
Catalog imageIn-Situ Spectroscopy & Diffraction
Photoelectrocatalytic XRD Reaction Cell for laboratory research and application-specific experimental configurations.
Reference imageResearch Cells & Fixtures
Photoelectrochemical cells selected around the optical path and electrode arrangement of the experiment.
Catalog imageBattery Fabrication Equipment
Pilot-Scale Cylindrical-Cell Production Line for laboratory and pilot-scale battery fabrication workflows.
Catalog imageBattery Fabrication Equipment
Pilot-Scale Pouch-Cell Production Line for laboratory and pilot-scale battery fabrication workflows.
Catalog imageBattery Fabrication Equipment
Pilot-Scale Prismatic-Cell Production Line for laboratory and pilot-scale battery fabrication workflows.
Reference imageCatalysts & Inks
Platinum black for electrode formulations requiring a specified unsupported platinum catalyst.
Reference imageElectrodes & Holders
Platinum mesh and gauze electrodes selected by sheet size, construction and laboratory cell mounting.
Reference imageElectrodes & Holders
Platinum plate electrodes for experiments requiring a solid electrode geometry and a defined exposed area.
Reference imageElectrodes & Holders
An electrode holder selected around the platinum plate thickness, width and connection point.
Reference imageElectrodes & Holders
A platinum working electrode selected by exposed geometry, holder dimensions and the laboratory measurement.
Reference imageCatalysts & Inks
Platinum–ruthenium black catalyst ordered to a stated composition and material specification.
Brochure photoCatalysts & Inks
Carbon-supported platinum–ruthenium catalyst for a specified composition and laboratory formulation.
Reference imageBattery Components
PE battery separator requirements selected by grade, thickness and the required laboratory format.
Reference imageBattery Components
PP separator materials for laboratories specifying a particular grade and cell assembly format.
Reference imageBattery Components
Pouch-cell holders defined by the cell envelope, tab arrangement and required test interface.
Catalog imageBattery Fabrication Equipment
Pouch-Cell Fabrication Equipment Line for laboratory and pilot-scale battery fabrication workflows.
Catalog imageIn-Situ Spectroscopy & Diffraction
Pouch-Cell In-Situ Mass Spectrometry Cell for laboratory research and application-specific experimental configurations.
Reference imageBattery Components
Trilayer PP–PE–PP separator requirements for laboratory cells, with dimensions and material data specified.
Reference imageBinders
PVDF binder requirements for electrode formulations with a stated polymer grade and processing route.
Catalog imageIn-Situ Spectroscopy & Diffraction
Raman–Mass Spectrometry Tandem Cell for laboratory research and application-specific experimental configurations.
Catalog imageJoule Heating Systems
Rapid Joule Heating Furnace for laboratory research and application-specific experimental configurations.
Reference imageElectrodes & Holders
A saturated calomel reference electrode ordered with its required junction, body and connection details.
Reference imageBinders
SBR binder enquiries for electrode formulations, with the grade and required supply form defined.
Reference imageElectrodes & Holders
An electrode holder selected around the printed strip outline and electrical pad pattern.
Reference imageElectrodes & Holders
Screen-printed electrode formats for sensing and electrochemical research, selected by electrode layout and contact interface.
Catalog imageBattery Characterisation
Solid-State Battery In-Situ AFM Cell for laboratory research and application-specific experimental configurations.
Reference imageResearch Cells & Fixtures
Laboratory fixtures for solid-state battery experiments with defined specimen geometry and contact requirements.
Range photoElectrodes & Holders
An electrode holder selected around the stainless steel sample dimensions and the required isolation.
Reference imageFoams, Felts & Foils
Porous stainless steel foam specified by thickness, cut size and pore-structure requirements.
Reference imageFoams, Felts & Foils
Thin stainless steel foil selected by alloy grade, thickness and dimensions.
Range photoElectrodes & Holders
Stainless steel working electrodes specified by alloy grade, exposed area and the laboratory cell interface.
Reference imageCarbon Materials & GDL
Super P conductive-carbon enquiries with the exact grade, quantity and documentation specified by the laboratory.
Catalog imageBattery Characterisation
TEM In-Situ Liquid Cell System for laboratory research and application-specific experimental configurations.
Catalog imageResearch Cells & Fixtures
T-type laboratory test cells with a third-electrode connection specified for the intended experiment.
Reference imageFoams, Felts & Foils
Tin foil supplied against a defined thickness, size and research-material specification.
Reference imageFoams, Felts & Foils
Porous titanium foam specified by thickness, cut size and pore-structure requirements.
Catalog imageResearch Cells & Fixtures
Compression-type laboratory battery cells for a defined two-electrode arrangement, often described as Swagelok-type cells.
Catalog imageIn-Situ Spectroscopy & Diffraction
XRD Tensile and Compression Sample Stage for laboratory research and application-specific experimental configurations.
Reference imageFoams, Felts & Foils
Zinc foil for zinc-electrode research and thin-metal sample preparation.
Catalog imageBattery Characterisation
Zinc-Air Three-Electrode In-Situ XAFS Cell for laboratory research and application-specific experimental configurations.
Catalog imageResearch Cells & Fixtures
An acrylic metal-air battery test cell with gas-circulation support and 30 mL or 50 mL catalog options.
Catalog imageResearch Cells & Fixtures
A second acrylic metal-air test-cell configuration with gas circulation and selectable working volume.
Try a shorter product name, model or method. You can also browse another category.
View all products