SSI · TEST & MEASUREMENT

Cable Testing Equipment: VLF, Hipot & Cable Fault Location

Choose equipment by the job: insulation measurement, withstand testing, dielectric-loss measurement or fault location. Compare the listed SSI families before selecting a portable, trolley or vehicle-based configuration.

Cable fault location configurations

Model references and functions below come from the approved SSI electrical/HV catalogue. Open the product for its source page and enquiry options.

Instrument familyCatalogue modelsFunction and selectionSource
Cable Fault Location SystemHZ-A10 / HZ-G35A / HZ-B / HZ-R10Modular cable-fault investigation and pinpointing. Specify cable construction, network voltage, fault types and modules.Catalogue p29
Pushcart Cable Fault TestersHZ-A50 / HZ-A52Trolley-based cable-fault testing. Specify cable voltage, length, fault types and location accessories.Catalogue p28
Vehicle-Mounted Cable Fault Test SystemHZ-A40Integrated vehicle-mounted cable testing. Specify network voltage, fault-location functions and vehicle fit-out scope.Catalogue p28

Insulation and withstand test equipment

Model references and functions below come from the approved SSI electrical/HV catalogue. Open the product for its source page and enquiry options.

Instrument familyCatalogue modelsFunction and selectionSource
Insulation Resistance TestersHZJY-5K-I / HZJY-15K / HZJY-20K / HZJY-30K / HZ3151 / HZ3251Electrical insulation resistance. Specify test voltage, resistance range and test-object capacitance.Catalogue p16
VLF Hipot TestersHZVLF / HZDPVery-low-frequency insulation withstand testing. Specify cable length, capacitance, voltage and frequency.Catalogue p18
VLF Hipot & Tan Delta TesterHZDPS 34KVVLF withstand and dielectric-loss measurement. Specify cable type, test voltage, capacitance and tan-delta requirements.Catalogue p18
DC Hipot TestersHZZGFDC insulation withstand testing. Specify test voltage, leakage-current measurement and load.Catalogue p17
AC/DC Hipot Test TransformersOil, gas or dry test-transformer configurationsTransformer-based insulation withstand testing. Specify AC/DC voltage, kVA, capacitance, duty and control-console scope.Catalogue p20
Series Resonance Withstand Test SetsHZXBSeries-resonance AC withstand testing. Specify test-object capacitance, voltage, frequency and reactor configuration.Catalogue p21

Prepare a useful equipment enquiry

Cable insulation type, rated voltage, length and capacitance where known, fault symptoms or required test purpose, applicable test method, site access, available input supply, portability and accessory requirements.

Request the exact model ratings, calibration documentation, leads, fixtures, software and supplied accessories. Family listings do not establish a single operating range or certification. Test voltage and procedure must be selected for the asset and applicable requirements by qualified personnel.

Product pages provide editable WhatsApp and email enquiries. Add required instruments to the basket for a combined request.

Selection questions

Are VLF testing and cable fault location the same function?

No. The catalogue describes VLF families for insulation withstand testing and, for the combined model, dielectric-loss measurement. Cable fault-location families serve a separate diagnostic task. State both requirements if you need both functions.

Does the catalogue identify the complete supplied system?

Confirm the selected model, measurement limits, accessories and installation needs in the quotation. Do not combine ratings from different variants.

Is a programmable DC supply the same as an insulation test set?

Specify the required test function, measurement and protection scope. For laboratory source applications, see the separate DC power supply selection guide.

Related equipment and guides

All electrical & high-voltage testing instruments · Test & Measurement

Transformer Testing Equipment: TTR, Winding Resistance & Oil Tests