SSI · TEST & MEASUREMENT

High-voltage DC power supply selection guide

Specify voltage, current and power together, then choose the source, regeneration and control functions your test requires. Compare approved SSI catalogue families for laboratory, power-electronics and automated test benches.

Start with the test, then select the source

For laboratory and ATE power tests, compare the MP programmable source with your required operating points. For source and regenerative-load operation, review HB or WB3000. For two independently adjustable outputs, review EVWBT and specify each channel separately. GP/WP provides a separate route from compact laboratory sources to higher-power installations.

These are Test & Measurement instruments. For curriculum-based demonstrators and teaching benches, use the separate EV Lab training-kit guide.

Compare the verified DC source families

Ranges below describe catalogue families, not one unit or a continuously available output envelope. Maximum voltage and maximum current are not necessarily available simultaneously. Confirm the exact model and its operating curve.

Approved Test & Measurement Portfolio, physical pages 5–9
Family and product detailsCatalogue specificationSelection contextSource
MP High-Voltage Programmable DC Supply80–2250 V; 1.5–15 kW; model dependentAuto-ranging programmable DC supplies with catalog models reaching 2250 V.Catalogue p8
HB Bidirectional Rack DC Supply100–1500 V; 5–30 kW; model dependentA 3U programmable source and regenerative load family for laboratory and automated testing.Catalogue p7
WB3000 Bidirectional DC Test Source12–1200 V; listed models 100–600 kWA regenerative DC source family for drive, controller and power-converter test benches.Catalogue p5
EVWBT Dual-Channel DC Test SourceTwo independently adjustable DC outputs; confirm per-channel modelTwo independently adjustable DC outputs for test benches operating at different voltage levels.Catalogue p6
GP / WP Regulated DC SupplyCompact GP 36–400 V; high-power examples to 800 VDC sources ranging from compact programmable units to high-power test installations.Catalogue p9

MP model examples: read all three ratings

The approved catalogue lists these specific configurations on physical page 8. They illustrate why a voltage-only enquiry is insufficient.

Separate model limits, not simultaneous maximum output
ModelVoltageCurrentPowerHeight
MP-003-15001500 V6 A3 kW2U
MP-015-10001000 V40 A15 kW3U
MP-015-22502250 V25 A15 kW3U

For example, 1500 V × 6 A is 9 kW, above the MP-003-1500’s listed 3 kW power limit. Those voltage and current maxima therefore cannot describe one simultaneous operating point. Request the operating envelope at your required voltage.

Variant to confirm: MP-015-1500 appears twice in the catalogue with 30 A and 40 A ratings. Specify the required current and obtain exact variant confirmation before ordering.

View MP source details and product-specific enquiry →

Applications and related test paths

  • Motor controllers, powertrains and energy-storage converters: WB3000 is described for these test applications; define power direction, transient demand and regeneration requirements.
  • EV electronics, DC switches and automated tests: HB provides a rack source/load path. Confirm the chosen model, communications and site installation.
  • Laboratory, production-line and ATE supply tests: MP provides programmable source operation. Specify control, measurement and discharge requirements separately.
  • Testing a device that delivers energy: review the EVWR regenerative electronic load. A load and a source have different test roles.
  • Emulating a battery: review EVWS / EVWB battery simulators, with chemistry, arrangement, SOC and interface requirements.
  • Cycling a real battery pack: review the WBTS battery pack test system; for cell-scale testing, see the battery cycler selection guide.

Send these details for a useful quotation

  1. DUT and application: converter, controller, supply, battery pack or other equipment.
  2. Required voltage/current operating points, continuous power, peak power and peak duration.
  3. Source-only or source/load operation; regeneration, discharge and independent-channel requirements.
  4. Available AC input, installation space, cooling and required protection/interlock scope.
  5. Control interfaces, test software, measurement accuracy and response requirements.
  6. Quantity, delivery destination and included cables, fixtures, sensing and integration scope.

Add a catalogue family from its product page to the enquiry basket. Include exact model and operating points in the requirements field. Email and WhatsApp routes prepare editable drafts; sending or submitting remains your choice.

Common selection questions

Does a 2250 V family entry mean every MP supply reaches 2250 V?

No. The catalogue lists MP-015-2250 as a particular configuration. Other MP models have different voltage, current and power limits.

Is a programmable DC source automatically regenerative?

Do not infer this from programmability. HB and WB3000 explicitly describe regenerative operation; confirm the required source/load capability for the exact quoted system.

Are communication options and accessories always included?

Supplied interfaces, discharge equipment, cables and integration must be itemized in the quotation. A family description does not establish the supplied scope.

Return to Test & Measurement · Browse power supplies, loads and simulators · Download the source portfolio